How to Clean Air Conditioning Evaporator Unit Properly


20 December 2018

There are a lot of articles written about how to clean air conditioning evaporator units.   Many advised  to use chemical foam;  some preferred to use the cleaning chemicals specially blended for air conditioning washing.   There are merits and demerits depending on how each method can remove the “dirt”.  This article will describe a method that will thoroughly clean the air conditioning evaporator. 

Where is this Evaporating Coil located?

The coil is always located indoors for split unit air conditioners.  It is always hidden inside the air grille box or cover and always behind the air filter as shown



When to do Chemical Cleaning?

The air conditioning unit will tell us with the following telltale signs:-

1)  The air conditioner is no longer as cold and;
2)  The fan speed needs to be turned high before one can feel any cold air blowing,  plus
3)  The air conditioner is making a louder air splashing noise and lastly;
4)  The compressor will turn off sooner before the set room temperature is reached (only for air conditioning unit that has anti-freezing control for the evaporating coil)

Why Compressor Cuts Off Sooner?

The air conditioner that has anti-freezing control will have  a thermal sensor attached to the returning refrigeration pipe.  If the coil is dirty,  the evaporator coil temperature will get lower and will eventually freeze up unless the temperature change is picked up by this thermal sensor which will automatically cut off the compressor operation.


What are the Traditional Methods?

a)  Foam Cleaning 

One would spray foam onto the coil and wait for about 10 to 15 minutes for the foam to work its way into the coil. After that, spray washing the coil with clean water or just leave for the condensate water to "drain"  the foam into the outlet drain.   This method is fast but does not allow the fan blades to be cleaned



b)  Chemical Spraying

One would just spray the chemical onto the coil and wait for about 10 to 15 minutes for the chemical to work into the coil,  then spray washing the chemical.  This method can be used to clean the fan blades.




Both methods are fast but they are not cleaning the coil thoroughly.  For proper cleaning,  one should clean the air condition evaporator unit  using “Chemical Bathing” method which is recommended to be done at least once every 10 years.

What is Chemical Bathing Method?

It is a cleaning method that pours chemical water over the coil to clean the coil thoroughly.  This method will involve some dismantling including the draining tray if one wants to conserve the chemical water for repeated cleaning;   otherwise,  one could just let chemical water drain out into the outlet drain.     

Preparation: 

 Besides having the necessary things such as a ladder,  paint or cleaning brushes,  cleaning rags and other preparation work such as switching off power supply etc,  one should have the following

Description
Action
Remark
(Double-click to enlarge)
1.   Chemical Cleaning Fluid
Available easily from Horme Store or any air conditioning hardware stores @ about SGD$15/= per 5 litres or gallon
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhLVBhHZXaNYAxxWnlh-yQqfQuCkIbe9_ENuaKIIaKG2fxn4jjX1UGkVcwyrASnxfE_JaXpH1OHmVkAH9vA7Jm8jMOqyNRx18yBhu4liRz4Spng9SIg7OznYvHSHP251HIy2kupht-0_LZ0/s1600/2018-12-19_19h30_05.jpg
2.  Plastic basin

https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjimBW2KHjLIi6D2QaFrkSAzCDhHpMejFaYMQbd2h7kwiAe9ISf9OvhL9ASa8TN424in-skp2wTwfmHgstwveVjcJ61wxZos7COuSeXn2f0IhrYoSzBoedAD-0crASTY5pbwnZGjXqus35o/s1600/2018-12-19_19h35_22.jpg
3.  Plastic tumbler or mug

https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjc_n2Z2xL3E-Mqm2nYOV3OjJHWAooxTfTi7JmKwfMMmxPAHw8u8e7av9JhQm132Ar9Iz_92fTAMiUW17cieCz17lsdUYDlIGwQpuyoS-7LbaRPfqogDglqZpmVZZJkx-hwI2w0_RirGy6d/s1600/2018-12-19_19h39_42.jpg
4.  Cotton buds

https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgHQSfP7Kzq5FYmRXeZnWISp-70zb_13SPWNwtIruztu8W_ZF7vcncwVBr_tjAzIKs8D1g6OPKGWt44BXukrNkW1iPOp58fJtb2M6UXwvQYCZ72fdrQH03gvlbHtNG0z2sBEaQgnFT9_jj7/s1600/2018-12-19_19h42_40.jpg
5.  Hand Gloves

To prevent hand and fingers from prolonged soaking in the chemical water

Step by Step 

using Panasonic Inverter Air Conditioner as an example

Description
Action
Remark
(Double-click to enlarge)
1.   Preparation work
1.  Switch off the power as safety precaution
2.  Remove the filter if necessary
3.  To make the chemical water,  mix one cup of chemical with about 5 cups of clean water in the plastic basic

2.  Dismantling the air grille cover
1.  Remove the plastic caps that covered up the 2 screws and remove the screws as shown;
2.  Lift to open the horizontal air vane to clear the grille cover;
3.  Hold both sides of the grille cover and pull it forward toward yourself
4.  If the cover could not be dislocated and removed easily,  try releasing the 3 plastic catch that holds the top of the grille cover as shown


https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiBeVwvl2Z4NBnxEEfEfVH6QedS3910oV3omHWl_gHt7sYESuSW7ISir2uJE0Az8h209hjVq_4AU67-4tcHm13P4p7Jad9wQRwyxdwu1VASXgiVWVbep7cuB63kdgoy5CPoQFhWo5rIh-jU/s1600/2018-12-19_21h38_04.jpg
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjldgIX2cf__sz5qMSZGq98zuyey5gmKWm9CGzSJsb9EILGpPFwNwghktNKNfBnb-3pWFKS6NZ7qtH2ezH_Pi_RvbLKsVSa9Jy3XEYH8uwSmuRjaW7-bWO4mKeLyWDSi5a6hCrx4jPPIMYq/s1600/2018-12-19_22h53_59.jpg
3.  Dismantling the draining tray
The draining tray and the air discharge grille is one complete unit. To dismantle
1.  Pull the air discharge grille downward to loosen  the tray unit from its seats
2.  Remove the drain hose that is connected to the draining tray
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhtDbX83sSbVDgxGriUxT44FWcYt0w5iuRTVxwyj0oh1uI8MfiVK6LMPpoZxuRCla1M0xI9Du-_NUCCOVV6OoGk63cS-JRn-5WouE3ad_oLMCRrFJiVo506gAd-Ob_ByMqUihyphenhyphenc1GHejn4T/s1600/2018-12-19_21h38_42.jpg


4.   Coil Surface Cleaning

1. Dip paint brush in chemical water and brush the fins in the same direction as and along the fins;
2.  Collect the chemical water at the bottom of the coil using the basin
3.  Repeat action until the fins are all cleaned and shining on the surface. 

5.  Doing Chemical Bath
1.  Use the plastic mug to pour the chemical water from the top of the coil and collect the water at the bottom of the coil using the basin
2.  Repeat for the rest of the fin and coil;  
Note:  A air or water pressure pump would be helpful to push the chemical water through the fins but it is not really necessary unless the coil is so stuck with dirt that cannot be cleaned by pouring water over the fins
6.  Water Rinsing
1.  Repeat step 5 but using clean water instead of chemical water
2.  Change the water as and when necessary for proper cleaning
The chemical water needs to be rinsed "thoroughly" so that it will not be left to “attack” the flimsy fins
7.   Fan Blade Cleaning
1.  Dip the cotton bud in chemical water and clean the blade leaf by leaf and blade by blade until all the dirt are removed
Note:  One could use chemical spray to soften the dirt before removing them either using water and follow up the cleaning by using cotton buds.
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjZd8MiRY5Vj2YC8HW8IR_o0a2Hih6yt30zufyWqAHnTCqhwHLsooM9ZIfyWPI3RGXP6ChaBLLtD38LFcj21W831t70s28iEUvq8B8iQc93ZQpVg6mCev_AQzwptrQA9sIqI43tYj1sY5N2/s1600/2018-12-19_22h30_30.jpg
Important:  Never apply any pressure to the blade as a bend in the fan blade will put the wheel off balance,  creating unnecessary noises and vibrations during operation 

The alternative is to dismantle the cross flow fan by removing the screw as shown above and removing the fan bearing on the other end.  It would be necessary to dismantle the control board and also dislocate and lift up the evaporator to provide space to remove the cross flow fan.

8.  Completion and Assembly
1.  Reverse the dismantling procedure to fit all components back in place
2.  Switch on the air conditioner after placing a piece of cloth or plastic to catch the  dirt “flying” out from the fan blades.
If the coil has been properly cleaned,  one should notice that the air conditioner’s compressor will never stop operating until the set room temperature has been reached.

Result

Unfortunately,   there was no picture capturing the result of the cleaning but this picture did show up the shine of the lower part of the coil under the ceiling light.   The picture was intended to show the temporary shelve put up to ease the cleaning operation of the fan blade.  






Tuesday, December 18, 2018

Expecting a Santa Rally?


18 December 2018

Christmas is just one week away.  Many people in the stock forums are expecting a Christmas or a Santa rally.  Some took the chance to buy stocks that have been badly beaten,  hoping to make some money.   But will there be a Christmas & New Year rally?   Lets examine the past 4thquarter performance records of DOW in this article.

 

DOW @ Present

DOW just suffered one of the it's worst falls since 2008,  losing more than 4% in the last  2 straight trading days.   It has created 4 candlestick gaps and about to make a dreadful double top pattern to fall to 21,000 once it fall below 23,500.    




Why US Market Slump?


The markets are worrying about the following
  • Rising interest rates making borrowing more expensive
  • Slowing global  economic growth and weaker  China growth
  • Possible failing of Brexit
  • Rising of Italy’s budget crisis
  • Looming end of quantitative easing in Europe
  • Worrying U.S.-China trade relations
  • Slowing sign in earning growth of U.S. companies
  • Growing US deficits
  • Weakening banking and transport sectors
  • Falling housing markets

Will there be a Christmas Rally?

 Let examine the following table,  tabulating the 4th Quarter performance of DOW in the last 90 years from 1928 to 2018:

Last Quarter Performance


Date: 18 Dec 18

Year
DOW @ 1st of 4th Qrt
DOW @ date of record
DOW @ end of year
Gain/(Loss) Qrt to Date (QTD)
% Gain/(Loss) from date to end of year
% Gain/(Loss) @ end of 1st Qrt next year
1
1929
343
250
248
(27.14%)
14.63%
17.16%
2
1987
2,639
1,924
1,939
(27.08%)
3.31%
(1.35%)
3
1931
96
74
78
(22.86%)
(0.69%)
2.36%
4
1930
214
166
165
(22.67%)
4.08%
1.48%
5
1937
154
125
121
(18.79%)
(20.83%)
(17.93%)
6
2008
10,831
8,824
8,776
(18.53%)
(13.77%)
(15.78%)
7
1932
71
61
60
(15.01%)
(8.46%)
(6.56%)
8
1973
949
811
851
(14.51%)
4.38%
(1.01%)
9
1941
127
109
111
(13.79%)
(8.99%)
(11.74%)
10
2018
26,651
23,593
?
(11.48%)
?
?
11
2011
10,655
11,866
12,218
11.37%
11.34%
6.57%
12
1982
908
1,012
1,047
11.43%
11.72%
10.03%
13
1934
90
101
104
11.62%
(0.14%)
(3.57%)
14
2001
8,837
9,892
10,022
11.94%
5.18%
3.28%
15
1928
240
270
300
12.59%
14.29%
0.60%
16
1962
572
645
652
12.86%
5.74%
5.52%
17
1985
1,341
1,545
1,547
15.18%
17.75%
18.27%
18
1998
7,633
8,876
9,181
16.29%
10.26%
6.55%

It can be seen from the table that DOW has 10 occasions where its prices have fallen more than 10% in the 4th Quarter to 18 December.   DOW has also 8 occasions where  its prices have risen more than 10%.

In all these 10 losing occasions, ,  we observed the following:

1.  The fall in 2018 is the smallest @ around 12%; 

2.  The biggest fall on 1929 seen price fallen by about 30%;

3.  It is expected that when there is a bigger action,  there will be a big reaction.  In other words,  the bigger the fall,  the higher will be the rebounce for Christmas and New Year rally and also a better  performance in 1st quarter of the coming years;

4.   However,  when there is a fall less than 20% in 4th quarter ,  the coming 1st quarter performance will not be good.

Conclusion

Bearing unforeseen circumstances such as a cut in the Fed’s interest rate, it is very likely

1.  We would not have a good Christmas and New Year rally.  Even if we do have one,  it would be a mild one; 
2.  Do expect a lackluster 1st quarter in 2019.

Disclaimer:  This article is for information and  educational purposes.   Readers are advised to  conduct their own research and study to make their  own investment decisions.


==================================================================